Schneider 3 pole 60 Amp MCCB Circuit Breaker - PowerPact B, 60A, 3 pole, 25 kA, 600Y/347 VAC, UL, terminal nuts

PKR : 7,800.00 PKR : 13,000.00
In stock
SKU
3p60amp
More Information
Brand Schneider
In-Store Pickup Yes
Delivery Time 2 - 4 days
  • Short Circut protection
  • Overload protection
  • C curve: Suitable for household application
  • Breaking Capacity: 6000kA at 230/400 VAC as per IEC60898

Technical Specifications:

Main
range PowerPact
product name PowerPact B
device short name BJ 060
product or component type Circuit breaker
device application Distribution
Complementary
[In] rated current 60 A
Number of Poles 3P
protected poles description 3t
control type Toggle
breaking capacity code J
breaking capacity 100 kA at 208Y/120 V AC 50/60 Hz conforming to UL 489
100 kA at 240 V AC 50/60 Hz conforming to UL 489
65 kA at 480/277 V AC 50/60 Hz conforming to UL 489
65 kA at 480 V AC 50/60 Hz conforming to UL 489
25 kA at 600Y/347 V AC 50/60 Hz conforming to UL 489
50 kA at 250 V DC conforming to UL 489
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to UL 489
network frequency 50/60 Hz
[Ics] rated service breaking capacity 100 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
25 kA at 500...525 V AC 50/60 Hz conforming to IEC 60947-2
2.5 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2
65 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
trip unit technology Thermal-magneticTM-D,
continuous current rating 80 %
[Ui] rated insulation voltage 800 V conforming to IEC 60947-2
trip unit name TM-D
suitability for isolation Yes conforming to IEC 60947-2
utilisation category Category A
Mechanical durability 15000 cycles conforming to IEC 947-1 Annex K ed 5.2
Electrical durability 10000 cycles conforming to IEC 947-1 Annex K ed 5.2 at 440 V In
connection pitch 27 mm
AWG gauge AWG 14...AWG 8 aluminium/copper
AWG 6...AWG 3/0 aluminium/copper
local signalling Presence of auxiliary contacts: flag (green)
mounting mode Clip-on (35 mm symmetrical DIN rail)
By screws (plate)
electrical connection Terminal nut ON and OFF end
tightening torque 5 N.m for 2.5…16 mm² (AWG 14...AWG 4)
9 N.m for 25…95 mm² (AWG 3...AWG 3/0)
number of slots 1 slot(s) for auxiliary switch OF (plug-in)
1 slot(s) for voltage release MN or MX (plug-in)
1 slot(s) for alarm switch SD (plug-in)
Power wire stripping length 20 mm
Color Grey (RAL 7016)
9 mm pitches 9
height 137 mm
width 81 mm
depth 80 mm
net weight 0.924 kg

 

Write Your Own Review
You're reviewing:Schneider 3 pole 60 Amp MCCB Circuit Breaker - PowerPact B, 60A, 3 pole, 25 kA, 600Y/347 VAC, UL, terminal nuts
Your Rating